Rated Voltage 0.6/1kV or Less Parallel Clustered Aerial Insulated Cable

Uses:

The product is suitable to be used for power distribution and supply of electric transmission aerial line with rural power frequency low rated voltage 0.6/1kV or less. It possesses characteristics of weatherability, anti-aging, less wire consumption, easy for construction, short time limit for project and effectively preventing electricity theft and leakage etc, with relative better safety. The allowable long-term working temperature of cable conductor: PVC and polyethylene insulated aerial cable: 70 0 C; Cross-linked polyethylene insulated aerial cable: 90 0 C; When short circuit occurs, (the longest sustained time not over 5 seconds) the highest temperature of cable conductor shouldn't be above: PVC insulated aerial cable: 160 0 C; Polyethylene insulated aerial cable: 130 0 C; Cross-linked polyethylene insulated aerial cable: 250 0 C.

Model Number and Product Name:

Model Number

Product Name

BS-JKV-0.6/1

Rated Voltage 0.6/1kV Copper-Core PVC Insulated Parallel Clustered Insulated Aerial Cable

BS-JKLV-0.6/1

Rated Voltage 0.6/1kV Aluminum-Core PVC Insulated Parallel Clustered Insulated Aerial Cable

BS-JKY-0.6/1

Rated Voltage 0.6/1kV Copper-Core Polyethylene Insulated Parallel Clustered Insulated Aerial Cable

BS-JKLY-0.6/1

Rated Voltage 0.6/1kV Aluminum-Core Polyethylene Insulated Parallel Clustered Insulated Aerial Cable

BS-JKYJ-0.6/1

Rated Voltage 0.6/1kV Copper-Core Cross-Linked & Polyethylene Insulated Parallel Clustered Insulated Aerial Cable

BS-JKLYJ-0.6/1

Rated Voltage 0.6/1kV Aluminum-Core Cross-Linked & Polyethylene Insulated Parallel Clustered Insulated Aerial Cable

Performance Characteristics:

DC resistance and insulation resistance of cable conductor is conformity to the following list:

Nominal Cross Section mm 2

20 0 C DC Resistance Ω /km ≤

Insulation Resistance

M Ω .km ≥

Calculated Breakage Pulling Force of Cable (Single-Core)

N

Copper

Aluminum

Aluminum-Alloy

Steel-Core Aluminum Stranded Wire

Hard

Flexible

70 0 C

90 0 C

Hard Copper

Aluminum-Core

Aluminum-Alloy-Core

10

1.906

1.83

3.08

3.574

3.08

0.0067

0.67

3471

1650

2514

16

1.198

1.15

1.91

2.217

1.91

0.0065

0.65

5486

2512

4022

25

0.749

0.727

1.20

1.303

1.20

0.0054

0.54

8465

3762

6284

35

0.540

0.524

0.868

1.007

0.868

0.0054

0.54

11731

5177

8800

50

0.399

0.387

0.641

0.744

0.641

0.0046

0.46

16502

7011

12569

70

0.276

0.268

0.443

0.514

0.443

0.0040

0.40

23461

10354

17596

95

0.199

0.193

0.320

0.371

0.320

0.0039

0.39

31759

13727

23880

120

0.158

0.153

0.253

0.2964

0.253

0.0035

0.35

39911

17339

30164

150

0.128

-

0.206

0.239

0.206

0.0035

0.35

49505

21033

37706

185

0.1021

-

0.164

0.190

0.164

0.0035

0.35

61846

26732

46503

240

0.0777

-

0.125

0.145

0.125

0.034

0.34

79823

34679

60329

300

0.0619

-

0.100

0.110

0.100

0.0033

0.33

99788

43349

75411

Finished cable should stand the test of power frequency AC voltage: 3kV x 1min.