Add: W. Fengyi, Guanlin Town, Yixing City, Jiangsu Province
Tel: 0086-510-87291645
Fax: 0086-510-87294002
PC: 214252
http: //www.jscfdl.com
E-mail:cfdl@263.net

  Main Products

0.6/1~26/35kV Plastic Insulated & Highly

Flame Retarding (Oxygen Isolation Layer) Power Cable

Product Standard:

The product 0.6/1kV~26/35kV plastic insulated power cable is strictly manufactured following the GB/T12706-2002 “Rated Voltage 1kV—35kV Extrusion-Enveloped Solid Insulation Power Cable”, GB18380-2001 “Combustion Test for Bunched Wire & Cable”, GB/T17650-1998 “Test Method for Released Gas from Cable or Optical Fiber Cable When Materials Being Burning” and GB/T17651-1998 “Determination of Smoke Density of Burning Cable or Optical Fiber Cable Under Specified Conditions” and in the same time, the product also can be manufactured following the standards of IEC, BS, DN and USA Standard recommended by the International Electro-Technical Commission according to the requirements of customers.

Applicable Scope:

The product is suitable to be used for power distribution and supply of electric transmission line with power frequency rated voltage 0.6/1kV~26/35kV.

Service Features:

Power frequency rated voltage is 0.6/1kV~26/35kV.

Temperature 70 0 C is the allowable long-term highest working temperature of PVC insulated cable conductor and 90 0 C for XLPE insulated cable conductor; when short circuit occurs (the longest sustained time not over 5S), the highest temperature of cable conduct can't be above 250 0 C.

The ambient temperature of cable can't be below 0 0 C when it is being laid.

The flame retarding performance of cable can satisfy the index requirements specified in the Standard of GB18380.3-2001.

Cable with low-halogen should conform to the index requirements specified in the Standard of GB/T17650.2-1998 and GB/T17651-1998 except for GB18380.3-2001.

Cable with halogen-free and low-fume should conform to the index requirements specified in the Standard of GB/T17650.2-1998 and GB/T17651-1998 except for GB18380.3-2001.

The bending radius of cable: 3-core cable not smaller than 15-fold of external diameter of cable; single-core cable not smaller than 20-fold of external diameter of cable.

Selection of Rated Voltage of Cable:

If the rated voltage of cable is appropriate for the operation-state of cable-linking system, “U 0 /U (U m )” are indicated, all of them are effective values with application unit “kV”.

U 0 – rated power frequency voltage between ground cable conductor and metal screening material;

U- rated power frequency voltage between conductors of cable;

U m - the biggest value of the highest system-voltage of working cable.

U 0 Value Used for Three-phase system Cable Listed as Follows:

U

kV

U m

kV

U 0

Category-A & B System

Category-C System

1

1.2

0.6

0.6

3

3.6

1.8

3.6

6

7.2

3.6

6

10

12

6

8.7

15

17.5

8.7

12

20

24

12

18

35

42

21

26

Category-I------used for single-phase ground connection, and the fault time of system is not over 1min each time and the longest one not over 8 hours, the total fault occurring hours of the system not over 125 hours every year.

Category-II------used for the system with longer time of ground connection fault and also adopted for the places required for relative high insulation performance of cable.

Model Number of Cable:

Model Number

Product Name

Applicable Scope

Copper-Core

Aluminum-Core

GZR-VV

GZR-VLV

PVC Insulated & PVC Sheathed Highly Flame Retarding (Oxygen Isolation Layer) Power Cable

Used at the places where can't bear the mechanical external force, such as the indoor part, tunnel and cable channel. Single-core cable is not allowed to lay in magnetic pipes.

GZR-YJV

GZR-YJLV

Cross-Linked Polyethylene Insulated & PVC Sheathed Highly Flame Retarding (Oxygen Isolation Layer) Power Cable

GZR-DL-VV

GZR-DL-VLV

PVC Insulated & PVC Sheathed Low-Halogen & Highly Flame Retarding (Oxygen Isolation Layer) Power Cable

GZR-DL-YJV

GZR-DL-YJLV

Cross-Linked Polyethylene Insulated & PVC Sheathed Low-Halogen & Highly Flame Retarding (Oxygen Isolation Layer) Power Cable

GZR-WL-YJE

GZR-WL-YJLE

Cross-Linked Polyethylene Insulated & Polyolefine Sheathed Low-Fume & Halogen-Free Highly Flame Retarding (Oxygen Isolation Layer) Power Cable

GZR-VV22

GZR-VLV22

PVC Insulated & Steel-Tape Armored & PVC Sheathed Highly Flame Retarding (Oxygen Isolation Layer) Power Cable

Used at the places where can bear the mechanical external force, but can't bear big pulling force, such as the indoor part, tunnel and cable channel.

GZR-YJV22

GZR-YJLV22

Cross-Linked Polyethylene Insulated & Steel-Tape Sheathed Highly Flame Retarding (Oxygen Isolation Layer) Power Cable

GZR-DL-VV22

GZR-DL-VLV22

PVC Insulated & Steel-Tape Armored & PVC Sheathed Low-Halogen Highly Flame Retarding (Oxygen Isolation Layer) Power Cable

GZR-DL-YJV22

GZR-DL-YJLV22

Cross-Linked Polyethylene Insulated & PVC Sheathed Low-Halogen & Highly Flame Retarding (Oxygen Isolation Layer) Power Cable

GZR-WL-YJE23

GZR-WL-YJLE23

Cross-Linked Polyethylene Insulated & Steel-Tape Armored & Polyolefine Sheathed Low-Fume & Halogen-Free Highly Flame Retarding (Oxygen Isolation Layer) Power Cable

GZR-UKV32

GZR-YJLV32

Cross-Linked Polyethylene Insulated & Thin Steel-Wire Armored & PVC Sheathed Highly Flame Retarding (Oxygen Isolation Layer) Power Cable

Used at the places where can bear both of the mechanical external force and pulling force as well, such as the indoor part, tunnel and cable channel.

GZR-DL-YJV32

GZR-DL-YJLV32

Cross-Linked Polyethylene Insulated & Thin Steel-Wire Armored & PVC Sheathed Low-Halogen & Highly Flame Retarding (Oxygen Isolation Layer) Power Cable

GZR-WL-YJE33

GZR-WL-YJLE33

Cross-Linked Polyethylene Insulated & Thin Steel-Wire Armored & Polyolefine Sheathed & Low-Fume & Halogen-Free Highly Flame Retarding (Oxygen Isolation Layer) Power Cable

Production Scope

Production Scope of 0.6/1kV Highly Flame Retarding (Oxygen Isolation Layer) Cable:

Model Number

Voltage

Number of Cores

Nominal Cross Section mm 2

Copper-Core

Aluminum-Core

GZR-VV GZR-YJV

--

GZR-VV22 GZR-YJV22

--

GZR-VLV GZR-YJLV

GZR-VLV22 GZR-YJLV22

0.6/1

1

1.5~800

2.5~800

10~800

GZR-DL-VV GZR-DL-YJV

--

GZR-DL-VV22 GZR-DL-YJV22

--

GZR-DL-VLV GZR-DL-YJLV

GZR-DL-VLV22 GZR-DL-YJLV22

1.5~800

2.5~800

10~800

GZR-WL-YJE

--

GZR-WL-YJE23

--

GZR-WL-YJLE

GZR-WL-YJLE23

1.5~800

2.5~800

10~800

GZR-VV GZR-YJV

--

GZR-VV22 GZR-YJV22

--

GZR-VLV GZR-YJLV

GZR-VLV22 GZR-YJLV22

2

1.5~185

2.5~185

4~185

GZR-DL-VV GZR-DL-YJV

--

GZR-DL-VV22 GZR-DL-YJV22

--

GZR-DL-VLV GZR-DL-YJLV

GZR-DL-VLV22 GZR-DL-YJLV22

1.5~185

2.5~185

4~185

GZR-WL-YJE

--

GZR-WL-YJE23

--

GZR-WL-YJLE

GZR-WL-YJLE23

1.5~185

2.5~185

4~185

GZR-VV GZR-YJV

--

GZR-VV22 GZR-YJV22

--

GZR-VLV GZR-YJLV

GZR-VLV22 GZR-YJLV22

3

1.5~400

2.5~400

4~400

GZR-DL-VV GZR-DL-YJV

--

GZR-DL-VV22 GZR-DL-YJV22

--

GZR-DL-VLV GZR-DL-YJLV

GZR-DL-VLV22 GZR-DL-YJLV22

1.5~400

2.5~400

4~400

GZR-WL-YJE

--

GZR-WL-YJE23

--

GZR-WL-YJLE

GZR-WL-YJLE23

1.5~400

2.5~400

4~400

GZR-VV GZR-YJV

--

GZR-VV22 GZR-YJV22

--

GZR-VLV GZR-YJLV

GZR-VLV22 GZR-YJLV22

4

3+1

1.5~400

2.5~400

2.5~400

GZR-DL-VV GZR-DL-YJV

--

GZR-DL-VV22 GZR-DL-YJV22

--

GZR-DL-VLV GZR-DL-YJLV

GZR-DL-VLV22 GZR-DL-YJLV22

1.5~400

2.5~400

2.5~400

GZR-WL-YJE

--

GZR-WL-YJE23

--

GZR-WL-YJLE

GZR-WL-YJLE23

1.5~400

2.5~400

2.5~400

GZR-VV GZR-YJV

--

GZR-VV22 GZR-YJV22

--

--

GZR-VLV GZR-YJLV

--

GZR-VLV22 GZR-YJLV22

5

3+2

4+1

1.5~300

2.5~300

2.5~300

4~300

GZR-DL-VV GZR-DL-YJV

--

GZR-DL-VV22 GZR-DL-YJV22

--

--

GZR-DL-VLV GZR-DL-YJLV

--

GZR-DL-VLV22 GZR-DL-YJLV22

1.5~300

2.5~300

2.5~300

4~300

GZR-WL-YJE

--

GZR-WL-YJE23

--

GZR-WL-YJLE

--

GZR-WL-YJLE23

1.5~300

2.5~300

2.5~300

4~300

Production Scope of 1.8/3~26/35kV Highly Flame Retarding (Oxygen Isolation Layer) Cable:

Model Number

No. of Cores

Voltage

Copper-Core

Aluminum-Core

1.8/3

3.6/6

6/6

6/10

8.7/10

8.7/15

~12/20

18/30

~26/35

Nominal Cross Section

GZR-YJV GZR-DL(WL)-YJV

GZR-YJV22 GZR-DL(WL)-YJV22

GZR-YJV32 GZR-DL(WL)-YJV32

GZR-YJLV GZR-DL(WL)-YJLV

GZR-YJLV22 GZR-DL(WL)-YJLV22(23)

GZR-YJLV32 GZR-DL(WL)-YJLV32(33)

1

10~630

10~630

10~630

25~630

25~630

25~630

25~630

25~630

25~630

35~630

35~630

35~630

35~630

35~630

35~630

GZR-YJV GZR-DL(WL)-YJV

GZR-YJV22 GZR-DL(WL)-YJV22

GZR-YJV32 GZR-DL(WL)-YJV32

GZR-YJLV GZR-DL(WL)-YJLV

GZR-YJLV22 GZR-DL(WL)-YJLV22

GZR-YJLV32 GZR-DL(WL)-YJLV32

3

10~500

10~500

10~500

25~500

25~500

25~500

25~500

25~500

25~500

35~500

35~500

35~500

35~500

35~500

35~500

Note: the single-core armored highly flame retarding cable (with oxygen isolation layer) cable is only used for DC system, if for AC system, non-magnetic material or magnetic protection measures need be adopted for armoring layer.