Cross-Linked Polyethylene Insulated
& PVC Sheathed (Flame Retarding) Control Cable
Uses:
The product can be adopted as the signal, circuit protection and measurement-used control cable with power frequency rated voltage 0.6/1kV or less. Such flame retarding cable especially suits for the key places required high safety coefficient, such as nuclear power station, subway and high storied building etc.
Model Number and Product Name:
Model Number |
Product Name |
KYJV |
Copper-Core Cross-Linked Polyethylene Insulated & PVC Sheathed Control Cable |
KYJVP |
Copper-Core Cross-Linked Polyethylene Insulated Copper-Wire Braided & Shielded PVC Sheathed Control Cable |
KYJVP2 |
Copper-Core Cross-Linked Polyethylene Insulated & Copper-Strip Shielded & PVC Sheathed Control Cable |
KYJVP3 |
Copper-Core Cross-Linked Polyethylene Insulated Aluminum-Plastic Composite-Strip Shielded & PVC Sheathed Control Cable |
BLYJV22 |
Copper-Core Cross-Linked Polyethylene Insulated Steel-Tape Armored & PVC Sheathed Control Cable |
KYJVP-22 |
Copper-Core Cross-Linked Polyethylene Insulated Copper-Wire Braided & Shielded Steel-Tape Armored PVC Sheathed Control Cable |
KYJVP2-22 |
Copper-Core Cross-Linked Polyethylene Insulated & Copper-Strip Shielded & Steel-Tape Armored PVC Sheathed Control Cable |
KYJVP3-22 |
Copper-Core Cross-Linked Polyethylene Insulated & Aluminum-Plastic Composite-Strip Shielded & Steel-Tape Armored PVC Sheathed Control Cable |
Single conductor (A) or 7-strand cross (B) can be adopted as cable conductor.
Flame retarding cable can be manufactured following the Standard of GB/T18380.3-2001 (same effect with that of IEC60332) according to the requirements of users, and the relative specifications are divided into Category-A, B and C, and the designations of “ZRA-”, “ZRB-” and “ZR(C )-” can be added in the front of the original model number of cables.
Performance Characteristics:
DC resistance and insulation resistance of cable conductor is in conformity to the following list:
Nominal Cross Section
mm2 |
DC ResistanceΩ/km at 200C
≤ |
Insulation Resistance MΩ.km ≥ |
600/1000V |
200C |
900C |
0 |
24.7 |
1420 |
1.420 |
75 |
18.2 |
1280 |
1.280 |
1.0 |
12.1 |
1090 |
1.090 |
1.5 |
7.41 |
920 |
0.920 |
2.5 |
4.61 |
770 |
0.770 |
4 |
3.08 |
650 |
0.650 |
6 Core intervals and gap between core and screening material of finished cable should stand the test of power frequency AC voltage.
The performance of flame retarding cable should be in conformity to the Standard of GB/T18380.3-2001 (same effect with that of IEC60332). |