Add: W. Fengyi, Guanlin Town, Yixing City, Jiangsu Province
Tel: 0086-510-87291645
Fax: 0086-510-87294002
PC: 214252
http: //www.jscfdl.com
E-mail:cfdl@263.net

  Main Products

PVC Insulated & PVC Sheathed(Flame Retarding) Control Cable

Uses:
The product is suitable to be adopted as the daily-used electrical appliance, instrument, gauge and telecommunication equipment-used control cable with power frequency rated voltage 450/750kV or less.
The product also can be adopted as the signal, circuit protection and measurement-used control cable with power frequency rated voltage 0.6/1kV or less.

Model Number and Product Name:


Model Number

Product Name

KVV

Copper-Core PVC Insulated & PVC Sheathed Control Cable

KVVP

Copper-Core PVC Insulated & PVC Sheathed Copper-Wire Braided & Shielded Control Cable

KVVP2

Copper-Core PVC Insulated & PVC Sheathed Copper Strip Shielded Control Cable

KVV22

Copper-Core PVC Insulated & PVC Sheathed Steel-Tape Armored Control Cable

KVVR

Copper-Core PVC Insulated & PVC Sheathed Flexible Control Cable

KVVRP

Copper-Core PVC Insulated & PVC Sheathed Copper-Wire Braided & Shielded Flexible Control Cable

KVVP-22

Copper-Core PVC Insulated & PVC Sheathed Copper-Wire Braided & Shielded Steel-Tape Armored Control Cable

KVVP2-22

Copper-Core PVC Insulated & PVC Sheathed Copper-Strip Shielded & Steel-Tape Armored Control Cable

Single conductor (A) or 7-strand cross (B) can be adopted as the cable conductor.
Performance Characteristics:
Direct-current electric resistance and insulation resistance of cable conductor is in conformity to the following list:


Nominal Cross Section mm2

DC ResistanceΩ/km at 200C

Insulation Resistance MΩ.km ≥

450/750V

600/1000V

200C

700C

200C

700C

0.75

24.7

12.0

0.012

14.2

0.0142

1.0

18.2

11.0

0.0110

12.6

0.0126

1.5

12.1

10.0

0.0100

11.0

0.0110

2.5

7.41

9.0

0.0090

9.31

0.0093

4

4.61

7.7

0.0077

9.20

0.0092

6

3.08

6.5

0.0065

7.88

0.0078

Core intervals and gap between core and screening material of finished cable should stand the test of power frequency AC voltage.


450/750V 3000V x 5min

600/1000V 3500V x 5min

The flame retarding control cable (“ZRA-“, “ZRB-“ and“ZR(C )-”) can be manufactured following the Standard of GB/T18380.3-2001 (same effect with that of IEC60332) according to different requirements of users.

 

苏ICP备05004533号 版权所有: 江苏长峰电缆有限公司